EDR-384SR|Pipetting System
Pipetting System EDR-384SR
Benchtop Multi-Pipetter
96-ch Starter Set
(Main unit + PC + 96-ch head)
- Compact system that can be installed on a clean bench.
- Easy table-based operations, including dispensing of reagent to plates, transfer of samples and medium exchange.
- High-speed operations with the 96/384-ch simultaneous dispensing.
- The column processing head can perform both horizontal and vertical dispensing into plates.
- Power outlets are provided on the left side of the main unit.They can be used as the power supply to stirrer and other devices, and can be turned on and off from a PC.
Areas to Which the System Has Been Applied

Drug discovery

Genomics

Cells

Clinical testing

Food inspection
Dispensing system | 96/384-ch independent cylinder system |
---|---|
Head | 96/384-ch disposable cassette type Colum processing tip holder type |
Dispensing volume | 1 - 40 μL (384-ch) 1 - 50 μL (96-ch) 10 - 300 μL (96-ch) |
Compatible plates | Various 96/384 micro-well plates deep well plates, PCR plates, etc. |
Number of stages | 3 stages (when plates are placed lengthwise |
Accuracy | Within ± 2% (At the time of dispensing of 100 μL) |
Dispensing precision | CV 3% or less (At the time of dispensing of 100 μL) |
Power supply | AC100V 50/60Hz |
Control | Dedicated PC software (touch panel type) |
Dimensions | W300mm×D290mm×H330mm |
Weight | about 14 kg (Main unit only) |
Watch YouTube videos in Chrome or Firefox.
Product Introduction Video (3:21 minute explanation) “EDR-384SR 2-Unit Control”
Watch YouTube videos in Chrome or Firefox.
QWhen the system is installed in a safety cabinet, will it be affected by UV?
AA The main unit of the system will not be affected, but if resin products (tips, cables, etc.) are exposed to UV for a long period of time, they may be affected.
QHow long is the processing time?
AThe processing time is about 20 sec at 1:1 dispensing, but it depends on conditions.
QIs it possible to exchange media for cells that are easy to peel off?
AYes.This system has been used for the automation of medium exchange for HEK cells, which are very easy to peel off.
Please finely set suction speed, tube wall suction, and other parameters to use this system for such purposes.
Please finely set suction speed, tube wall suction, and other parameters to use this system for such purposes.
Product Images
One-touch replaceable cylinder and head

Compact size

When connected with a stacker

EDR-384SR + Stacker + EDR-384SR

Plate placed crosswise

Plates placed lengthwise

Disposable cassette type head

Software main screen
(Plates placed lengthwise)

Software main screen (Plates placed lengthwise)